These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Evaluation of the 13C-triolein breath test for fat malabsorption in adult patients with cystic fibrosis.
    Author: Ritz MA, Fraser RJ, Di Matteo AC, Greville H, Butler R, Cmielewski P, Davidson G.
    Journal: J Gastroenterol Hepatol; 2004 Apr; 19(4):448-53. PubMed ID: 15012784.
    Abstract:
    BACKGROUND AND AIMS: A simple non-invasive test not requiring the use of radioactive isotopes is required to assess fat malabsorption in adult cystic fibrosis (CF) patients. Breath tests using substrates labeled with 13C meet these conditions. The 14C-triolein breath test is sensitive and specific for measuring fat malabsorption, but involves radiation exposure. The aim of this study was to examine the utility of a test using a 13C label and to determine whether pancreatic replacement therapy would return the test to the values of a normal control group. METHODS: 13CO2 recovery was assessed after an overnight fast in six adult patients with CF, both with and without pancreatic enzyme replacement therapy (PERT) in the usual dose for a light snack, in a randomized order, on different days. Studies were also performed in eight healthy volunteers after oral ingestion. Subjects drank 50 mL of a liquid meal mixed with 200 microL 13C-triolein and breath samples were collected by blowing through a straw into collection tubes every 30 min for 6 h. The effect of gastric emptying was assessed by comparison of oral ingestion with intraduodenal infusion. Intra-individual variability was assessed in nine volunteers by repeating the breath test after drinking the test meal on a separate day. RESULTS: Compared with healthy subjects there was virtually no recovery of 13CO2 in CF patients without PERT. The median (interquartile range) cumulative percentage dose recovery (cPDR) at 6 h was 3% (0-8) in CF patients compared with 28% (22-41) in healthy controls (P < 0.01). Fat absorption was normalized (37%) (36-43) after ingestion of PERT. Gastric emptying delayed the peak in 13CO2 recovery, but there was no difference in the cPDR at 6 h. There was no difference in recovery between days 1 and 2. CONCLUSIONS: The 13C-triolein breath test is a simple and reproducible method to measure fat malabsorption. The test provides a screening technique for fat malabsorption in adult CF patients and may be useful for monitoring the lowest effective dose of PERT.
    [Abstract] [Full Text] [Related] [New Search]