These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Rapid determination of metformin in human plasma by liquid chromatography-tandem mass spectrometry method. Author: Chen X, Gu Q, Qiu F, Zhong D. Journal: J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Apr 05; 802(2):377-81. PubMed ID: 15018802. Abstract: A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method is described for quantitation of metformin in human plasma. After a simple, one-step protein precipitation using acetonitrile, metformin and the internal standard diphenhydramine were chromatographed on a C(8) column and detected by tandem mass spectrometry. An atmospheric pressure chemical ionization interface was chosen to reduce ion suppression from sample matrix components and provide high sensitivity. The method has a chromatographic total run time of 3.4 min and was linear within the range 2-2000 ng/ml. Intra- and inter-day precision, expressed as the relative standard deviation (R.S.D.), ranged from 4.4 to 5.7% and from 1.3 to 2.8%, respectively. Assay accuracy was less than 1% in terms of %RE (relative error). The assay was used to evaluate the pharmacokinetics of metformin after an oral administration of multicomponent formulation containing 500 mg metformin and 2.5 mg glyburide to 20 healthy volunteers.[Abstract] [Full Text] [Related] [New Search]