These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Effect of the Honan intraocular pressure reducer in sub-Tenon's anesthesia. Author: Vallance JH, Patton N, Ferguson A, Bennett HG. Journal: J Cataract Refract Surg; 2004 Feb; 30(2):433-6. PubMed ID: 15030837. Abstract: PURPOSE: To ascertain whether the Honan intraocular pressure reducer (HIPR) has an effect on the preoperative intraocular pressure (IOP), surgeon's assessment of anesthesia, and patients' analgesic experience when sub-Tenon's anesthesia is used for routine cataract surgery. SETTING: Princess Alexandra Eye Pavilion, Edinburgh, Scotland. METHOD: Forty-five eyes of 45 patients having routine phacoemulsification cataract surgery were randomized to receive 10 minutes of ocular compression using the HIPR or no compression after administration of sub-Tenon's anesthesia. The IOP was measured immediately before and immediately and 10 minutes after sub-Tenon's anesthesia administration using a standard technique. One surgeon who was masked to the randomization process performed all injections and completed a questionnaire on aspects of the anesthetic block. Patients scored their level of analgesia during surgery. RESULTS: The mean rise in IOP immediately after administration of sub-Tenon's anesthesia was 1.39 mm Hg +/- 3.91 (SD) (95% confidence interval +0.22 to 2.57; P =.021). In the 22 patients who received compression, there was a mean IOP reduction of 4.20 +/- 2.74 mm Hg at 10 minutes. The mean difference between the compression and no-compression groups at 10 minutes was 4.99 mm Hg (P<.0001). There was no difference in the surgeon's scores for any aspect of the sub-Tenon's anesthesia (P>.05). All patients reported good levels of analgesia. CONCLUSIONS: There was a significant reduction in IOP after compression using the HIPR. However, the rise in IOP after administration of sub-Tenon's anesthesia was small and the use of the HIPR did not make a significant difference in the effectiveness of the anesthesia to the surgeon or patients.[Abstract] [Full Text] [Related] [New Search]