These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: MRI-guided breast biopsy: clinical experience with 14-gauge stainless steel core biopsy needle.
    Author: Chen X, Lehman CD, Dee KE.
    Journal: AJR Am J Roentgenol; 2004 Apr; 182(4):1075-80. PubMed ID: 15039191.
    Abstract:
    OBJECTIVE: Core needle biopsy has proven advantages for wire localization and excision; however, MRI-guided core biopsy has been limited by less satisfactory sampling efficiency and less availability of MRI-compatible biopsy needles. We evaluated the feasibility and diagnostic yield of MRI-guided biopsy using 14-gauge stainless steel core biopsy needles and MRI-compatible coaxial sheaths in a closed 1.5-T scanner. MATERIALS AND METHODS: Thirty-five consecutive breast biopsies performed in 29 women between March 2001 and August 2002 were retrospectively reviewed. For each procedure, an MRI-compatible sheath was placed under MRI guidance using a dedicated breast coil and biopsy guidance system. With the patient out of the magnet, a 14-gauge steel core biopsy needle was used to obtain multiple samples. Lesion characteristics, including size, morphology, and enhancement, were recorded. Histology of all the lesions was obtained; and surgical, imaging, or clinical follow-up was performed. RESULTS: Targeted masses and enhancing foci ranged from 3 to 17 mm. Regional enhancement ranged from 14 to 70 mm. Thirty-four of the 35 biopsies were technically successful. Histology revealed malignancy in eight lesions (23%), atypical ductal hyperplasia in five lesions (14%), and benign entities in 21 lesions (60%). Surgery confirmed all eight core biopsies with malignant findings. Two of five lesions with atypical ductal hyperplasia were upgraded to malignancy after surgery. CONCLUSION: This new method of MRI-guided breast biopsy with a 14-gauge stainless steel core biopsy needle and a closed 1.5-T MRI scanner is feasible, safe, and effective and produces satisfactory diagnostic yield. This method offers an alternative to MRI-guided wire localization and to MRI-guided core biopsy with nonferrous needles.
    [Abstract] [Full Text] [Related] [New Search]