  • Title: Development of SH-SAW sensors for underwater measurement.
    Author: Kwon Y, Roh Y.
    Journal: Ultrasonics; 2004 Apr; 42(1-9):409-11. PubMed ID: 15047320.
    Abstract:
    We developed SH (shear horizontal) surface acoustic wave (SAW) sensors to detect protein molecules in liquid solutions applying a particular antibody thin film on the delay line of transverse SAW devices. The antibody investigated was human-immuno-globulin G (HigG) to hold the antigens (anti-HigG) in the protein solution to be measured. The sensor showed stable response to the mass loading effects of the anti-HigG molecules with the sensitivity up to 10.8 ng/ml/Hz.