These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Flow volume and shunt quantification in pediatric congenital heart disease by real-time magnetic resonance velocity mapping: a validation study. Author: Körperich H, Gieseke J, Barth P, Hoogeveen R, Esdorn H, Peterschröder A, Meyer H, Beerbaum P. Journal: Circulation; 2004 Apr 27; 109(16):1987-93. PubMed ID: 15066942. Abstract: BACKGROUND: Flow quantification in real time by phase-contrast MRI (PC-MRI) may provide unique hemodynamic information in congenital heart disease, but available techniques have important limitations. We sought to validate a novel real-time magnetic resonance flow sequence in children. METHODS AND RESULTS: In 14 pediatric patients (mean age 5.2+/-2.0 years) with cardiac left-to-right shunt, pulmonary (Q(p)) and aortic (Q(s)) flow rates were determined by nontriggered free-breathing real-time PC-MRI with single-shot echo-planar imaging combined with sensitivity encoding, which yielded 25 phase images per second at 2.7x2.7-mm in-plane resolution (field of view 30x34 cm2). Over a 9.5-second period that included 2 to 5 respiratory cycles, 16.6+/-2.6 subsequent stroke volumes (range 13 to 22) were acquired in each vessel. Results were compared with conventional retrospectively ECG-gated PC-MRI. Mean Q(p)/Q(s) by conventional PC-MRI was 1.91+/-0.64, and it was 1.94+/-0.68 (mean+/-SD) by real-time PC-MRI. For blood flow rate through pulmonary artery and aorta, we found differences of 2% to 3% (Bland-Altman analysis), with lower limits of agreement of -11% to -13% (mean-2 SD) and upper limits of 18% to 19% (mean+2 SD), which demonstrated good agreement between both methods. Mean difference for Q(p)/Q(s) was 1%, with limits of agreement ranging between -18% and 22% (mean+/-2 SD). High repeatability but some flow overestimation was observed in vitro (pulsatile flow phantom) with real-time PC-MRI, whereas conventional PC-MRI was accurate. Beat-to-beat stroke-volume variation was 6.1+/-2.3% in vivo and 3.7+/-0.3% in vitro. CONCLUSIONS: Beat-to-beat quantification of pulmonary and aortic flows and hence left-to-right shunt within a few seconds is reliable by nontriggered real-time PC-MRI with echo-planar imaging and sensitivity encoding. Good spatial/temporal resolution and a large field of view may render the sequence valuable for multiple applications in congenital heart disease.[Abstract] [Full Text] [Related] [New Search]