These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: The effect of wrist orthoses on forearm muscle activity. Author: Johansson L, Björing G, Hägg GM. Journal: Appl Ergon; 2004 Mar; 35(2):129-36. PubMed ID: 15105074. Abstract: A general hypothesis is that a wrist orthosis reduces the wrist extensor muscle load. The aim of this study was to investigate the effects of a completely stiff wrist orthosis (SO) and a commercially available wrist orthosis (CO) on flexor and extensor electromyographic (EMG)-activity in a standardised intermittent gripping task and during standardised manual work tasks. Surface EMG from two forearm flexor and two extensor muscles was recorded. The target grip forces were 5%, 20% and 40% of maximal voluntary contraction (MVC). During the grip contraction phase CO had no effect on the EMG-readings. SO resulted in higher EMG activity than when gripping with CO and with no orthosis (NO), especially when gripping with 40% MVC. During the relaxation phase neither CO nor SO had any effect on the extensors. For the flexors the SO gave higher EMG-readings than when gripping with CO and NO, especially at 40% MVC. In conclusion the wrist orthoses tested did not reduce the EMG-activity from the flexors or the extensors during gripping or manual tasks.[Abstract] [Full Text] [Related] [New Search]