These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Post-dilatation intravascular brachytherapy trials on hypercholesterolemic rabbits using 32P-phosphate solutions in angioplasty balloons. Author: Walichiewicz P, Wilczek K, Petelenz B, Jacheć W, Jochem J, Tomasik A, Bilski P, Gaca P, Banaszczuk J, Ihnatowicz J, Wodniecki J. Journal: Cardiovasc Intervent Radiol; 2004; 27(1):42-50. PubMed ID: 15109228. Abstract: PURPOSE: Response of peripheral arteries to post-dilatation intravascular brachytherapy (IVBT) using 32P liquid sources was studied in a rabbit model. METHODS: The applied sources were angioplasty balloons filled with aqueous solutions of Na2H32PO4, NaCl and iodinated contrast. Dose distribution was calibrated by thermoluminescence dosimetry. The uncertainty of in vitro determinations of the activity-dose dependence was +/- 15-30%. The animal experiments were performed on rabbits with induced hypercholesterolemia. The 32P sources were introduced into a randomly chosen (left or right) iliac artery, immediately after balloon injury. Due to the low specific activity of the applied sources, the estimated 7-49 Gy doses on the internal artery surface required 30-100 min irradiations. A symmetric, balloon-occluded but non-irradiated artery of the same animal served as control. Radiation effects were evaluated by comparing the thicknesses of various components of irradiated versus untreated artery walls of each animal. RESULTS: The treatment was well tolerated by the animals. The effects of various dose ranges could be distinguished although differences in individual biological reactions were large. Only the 49 Gy dose at "zero" distance (16 Gy at 1.0 mm from the balloon surface) reduced hypertrophy in every active layer of the artery wall. The cross-sectional intimal thicknesses after 7, 12, 38 and 49 Gy doses were 0.277, 0.219, 0.357 and 0.196 mm2 respectively, versus 0.114, 0.155, 0.421 and 0.256 mm2 in controls (p < 0.05). The lowest radiation dose on the intima induced the opposite effect. Edge intimal hyperplasia was not avoided, which agrees with other reports. The edge restenosis and the variability of individual response to identical treatment conditions must be considered as limitations of the post-dilatation IVBT method. CONCLUSION: Only application of highest irradiation doses was effective. The irradiation dose should be planned and calculated for adventitia.[Abstract] [Full Text] [Related] [New Search]