These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Interlaboratory reliability of microimmunofluorescence test for measurement of Chlamydia pneumoniae-specific immunoglobulin A and G antibody titers. Author: Littman AJ, Jackson LA, White E, Thornquist MD, Gaydos CA, Vaughan TL. Journal: Clin Diagn Lab Immunol; 2004 May; 11(3):615-7. PubMed ID: 15138190. Abstract: To evaluate the reliability of Chlamydia pneumoniae-specific immunoglobulin G (IgG) and IgA antibody titers as measured by the microimmunofluorescence (MIF) test, we compared results from 392 individuals using a standard MIF protocol at two academic laboratories. The kappas for dichotomous titers (>/=16 versus <16) were 0.39 for IgA and 0.53 for IgG. Measurement error likely attenuates C. pneumoniae-disease associations; the magnitude of attenuation can be estimated from results of studies such as this one.[Abstract] [Full Text] [Related] [New Search]