These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter.
    Author: Scavée C, Jaïs P, Hsu LF, Sanders P, Hocini M, Weerasooriya R, Macle L, Raybaud F, Clementy J, Haïssaguerre M.
    Journal: Eur Heart J; 2004 Jun; 25(11):963-9. PubMed ID: 15172468.
    Abstract:
    BACKGROUND: Radiofrequency (RF) ablation of cavotricuspid isthmus (CTI) dependent flutter can be performed using different types of ablation catheters. It has been proposed that irrigated and large-tip catheters are capable of creating larger lesions, resulting in greater efficacy. This prospective, randomised clinical study compared the efficacy of irrigated and large-tip catheters of different designs. METHODS: Eighty patients (69 men, 66+/-11 years) undergoing de novo RF ablation of CTI-dependent flutter were randomised to ablation using one of the following catheters: (i) externally-irrigated 20), (ii) internally-cooled (n=20), (iii) single sensor, 8-mm tip (n=20), or (iv) double sensor, 8-mm tip (n=20). The study endpoint was the demonstration of bidirectional CTI conduction block within 12 min of cumulative RF delivery. Crossover to the externally-irrigated catheter was permitted if this was not achieved. The ablation and procedural parameters, safety and efficacy were compared. RESULTS: The primary endpoint was achieved in 64 patients (80%), including all 20 patients randomised to the externally-irrigated catheter. Crossover was required in 16 patients: 9 initially using the internally-cooled catheter (45%), 3 using single-sensor, 8-mm-tip (15%), and 4 using double-sensor, 8-mm-tip (20%) catheters. The higher initial failure rate with the internally-cooled-tip catheter was significant compared to the externally-irrigated (p = 0.001) and single-sensor, 8-mm-tip (p = 0.04) catheters. The externally-irrigated catheter achieved the study endpoint more frequently with fewer RF applications of shorter duration compared to the internally-cooled-tip catheter and 8-mm-tip catheters, the difference being significant compared with internally cooled ablation. No major complications were observed. CONCLUSION: Among commonly used ablation catheters, the externally-irrigated catheter has a higher efficacy for rapid achievement of CTI block.
    [Abstract] [Full Text] [Related] [New Search]