These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Phakic refractive lens implantation in high myopic patients: one-year results. Author: Pallikaris IG, Kalyvianaki MI, Kymionis GD, Panagopoulou SI. Journal: J Cataract Refract Surg; 2004 Jun; 30(6):1190-7. PubMed ID: 15177592. Abstract: PURPOSE: To evaluate the efficacy and safety of implantation of a new posterior chamber phakic refractive lens (PRL, Ciba Vision Surgical) in highly myopic eyes. SETTING: Department of Ophthalmology, Medical School, University of Crete, Vardinoyannion Eye Institute of Crete, Crete, Greece. METHODS: Thirty-four myopic eyes of 19 patients were treated for high myopia with implantation of a silicone PRL in the posterior chamber. Mean patient age was 29.0 years +/- 7.9 (SD) (range 18 to 44 years). Manifest refraction in spherical equivalent (MR), uncorrected (UCVA) and best corrected (BCVA) visual acuity (decimal scale), intraocular pressure, higher-order aberrations (root-mean-square [RMS] wavefront error measured with a Shack-Hartmann wavefront sensor WASCA analyzer [Carl Zeiss, Meditec]), possible complications, and subjective symptoms were evaluated. RESULTS: Phakic refractive lenses were successfully implanted in all eyes. Mean follow-up was 17.17 +/- 3.76 months (range 12 to 24 months). There was a statistically significant reduction in the MR (from -14.70 D +/- 2.65 D [range -20.75 D to -10.50 D] to -0.61 D +/- 0.89 D [range -2.25 D to 1.00 D]) (P<.001). Twenty-seven (79%) and 15 eyes (44%) were within +/-1.00 D and +/-0.50 D of target refraction, respectively. Mean UCVA significantly improved (from counting fingers to 0.62 +/- 0.28 (range 0.08 to 1.20) (P<.001). Mean BCVA also improved from 0.70 +/- 0.24 (range 0.10 to 1.00) to 0.85 +/- 0.24 (range 0.10 to 1.20) (P<0.001). Overall, there was a mean increase in BCVA of 1.5 +/- 1.5 lines (range loss of 2 lines to gain of 5 lines). There was no statistically significant difference in higher-order aberrations after PRL implantation (pre-PRL RMS: 0.18 microm +/- 0.08 microm [range 0.09 microm to 0.38 microm]; post-PRL RMS: 0.21 microm +/- 0.08 microm; [range 0.05 microm to 0.38 microm]) (P =.12). CONCLUSION: The PRL showed encouraging results in treating high myopia. Additional patients and longer follow-up period are needed to detect the long-term efficacy and safety of this refractive lens.[Abstract] [Full Text] [Related] [New Search]