These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [A case of incomplete endocardial cushion defect with mirror-image dextrocardia, IVC defect and azygos connection].
    Author: Nakahara H, Nagaoka H, Sakamoto T, Yamada T.
    Journal: Kyobu Geka; 1992 Sep; 45(10):913-6. PubMed ID: 1518208.
    Abstract:
    A case of incomplete endocardial cushion defect associated with mirror-image dextrocardia, IVC defect and azygos connection is reported. Intracardiac defect was corrected under moderate hypothermia with cardiopulmonary bypass. Three venous drainage cannulas were necessary to be indwelled into SVC, hepatic vein and right common iliac vein to maintain adequate venous drainage for extra-corporeal circulation. Thus, anomaly of venous system, which is commonly associated with mirror-image dextrocardia, must be recognized correctly and prepared before intracardiac correction.
    [Abstract] [Full Text] [Related] [New Search]