These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Influence of continuous positive airway pressure on sleep apnea-related desaturation in sleep apnea patients. Author: Sériès F, Cormier Y, Laforge J. Journal: Lung; 1992; 170(5):281-90. PubMed ID: 1518299. Abstract: To investigate the influence of nasal continuous positive airway pressure (CPAP) on apnea-related desaturation, we compared the sleep apnea-related desaturations obtained during a polysomnographic study before and during nasal CPAP in 15 sleep apnea patients. An individual desaturation curve was determined with a regression analysis by plotting the lowest SaO2 value reached during each apnea against its duration; these data were collected throughout the night. At baseline, we only considered the apneas with a preapneic SaO2 value greater than 90% and a minimal SaO2 value above or equal to 60%. For the CPAP study, the preapneic SaO2 value also had to be within 2% the baseline value for the apneas to be retained. Due to the restriction criteria imposed to characterize apnea-related SaO2 falls, residual apneas still had to be recorded with CPAP. These data were analyzed separately for obstructive apnea for non-rapid eye movement (REM) and REM sleep stages. A desaturation curve was obtained from 10 sec to a variable upper limit that corresponded to the longest apnea duration commonly reached during both baseline and CPAP for a given apnea-type and sleep stage. The individual apnea-related SaO2 fall was characterized by measuring a desaturation area corresponding to the area under the curve. It was expressed in % SaO2/sec of apnea. CPAP reduced the number of apneas per hour of sleep from 37.5 +/- 6.5 (mean +/- SEM) to 14.3 +/- 3.7 (p = 0.001), and improved the whole night SaO2 level as estimated by a cumulative SaO2 curve. The mean apnea duration was reduced from 22.9 +/- 1.5 sec at baseline to 16.8 +/- 0.5 sec during CPAP therapy (p = 0.005). The preapneic SaO2 value was 94.8 +/- 0.3% at baseline and 95.5 +/- 0.2% during CPAP (p = 0.5). The desaturation area decreased from 267 +/- 48% SaO2/sec at baseline to 152 +/- 41% SaO2/sec during CPAP (p less than 0.001). We conclude that CPAP improves the apnea-related desaturation independently of the shortening of apneas and of any difference in the preapneic SaO2 value.[Abstract] [Full Text] [Related] [New Search]