These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Clinical outcomes of stereotactic radiotherapy for stage I non-small cell lung cancer using a novel irradiation technique: patient self-controlled breath-hold and beam switching using a combination of linear accelerator and CT scanner. Author: Onishi H, Kuriyama K, Komiyama T, Tanaka S, Sano N, Marino K, Ikenaga S, Araki T, Uematsu M. Journal: Lung Cancer; 2004 Jul; 45(1):45-55. PubMed ID: 15196734. Abstract: We have developed a novel irradiation technique for lung cancer that combines a linear accelerator and CT scanner with patient-controlled breath-hold and radiation beam switching. We applied this technique to stereotactic three-dimensional (3D) conformal radiotherapy for stage I non-small cell lung cancer (NSCLC) and evaluated the primary therapeutic outcomes. A total of 35 patients with stage I (15 IA, 20 IB) primary NSCLC (20 adeno, 13 squamous cell, and 2 others) were treated with this technique. Patients ranged from 65 to 92 years old (median, 78 years). Twenty-three (66%) patients were medically inoperable due to mainly chronic pulmonary disease or high age. Three-dimensional treatment plans were made using 10 different non-coplanar dynamic arcs. The total dose of 60 Gy was delivered in 10 fractions (over 5-8 days) at the minimum dose point in the planning target volume (PTV) using a 6 MV X-ray. After adjusting the isocenter of the PTV to the planned position by a unit comprising CT and linear accelerator, irradiation was performed under patient-controlled breath-hold and radiation beam switching. All patients completed the treatment course without complaint. Complete response (CR) and partial response (PR) rates were 8/35 (23%) and 25/35 (71%), respectively. Pulmonary complications of National Cancer Institute-Common Toxicity Criteria grade >2 were noted in three (9%) patients. During follow-up (range, 6-30 months; median, 13 months), two (6%) patients developed local progression and five (14%) developed distant or regional lymph node metastases. Two-year overall survival rates for total patients and medically operable patients were 58 and 83%, respectively. In conclusion, this new irradiation technique, utilizing patient-controlled radiation beam switching under self-breath-hold after precise alignment of the isocenter, allows safe high-dose stereotactic radiotherapy with sufficient margins around the CTV and reduced treatment times. Based on the initial results, excellent local control with minimal complications is expected for stage I NSCLC.[Abstract] [Full Text] [Related] [New Search]