These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Image quality improvement in a hard X-ray projection microscope using total reflection mirror optics.
    Author: Mimura H, Yamauchi K, Yamamura K, Kubota A, Matsuyama S, Sano Y, Ueno K, Endo K, Nishino Y, Tamasaku K, Yabashi M, Ishikawa T, Mori Y.
    Journal: J Synchrotron Radiat; 2004 Jul 01; 11(Pt 4):343-6. PubMed ID: 15211041.
    Abstract:
    A new figure correction method has been applied in order to fabricate an elliptical mirror to realize a one-dimensionally diverging X-ray beam having high image quality. Mutual relations between figure errors and intensity uniformities of diverging X-ray beams have also been investigated using a wave-optical simulator and indicate that figure errors in relatively short spatial wavelength ranges lead to high-contrast interference fringes. By using a microstitching interferometer and elastic emission machining, figure correction of an elliptical mirror with a lateral resolution close to 0.1 mm was carried out. A one-dimensional diverging X-ray obtained using the fabricated mirror was observed at SPring-8 and evaluated to have a sufficiently flat intensity distribution.
    [Abstract] [Full Text] [Related] [New Search]