These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Force-deflection comparison of superelastic nickel-titanium archwires.
    Author: Mallory DC, English JD, Powers JM, Brantley WA, Bussa HI.
    Journal: Am J Orthod Dentofacial Orthop; 2004 Jul; 126(1):110-2. PubMed ID: 15224067.
    Abstract:
    This in vitro study compared the force-deflection behavior of 6 superelastic nickel-titanium orthodontic archwires (0.016 x 0.022 in) under controlled moment and temperature. To simulate leveling, maxillary canine brackets and first molar tubes were bonded in such a manner as to remove the tip and angulation from the system. The wires (n = 10) were passively self-ligated into stainless steel brackets attached to an acrylic jig to simulate the maxillary arch. A testing machine recorded deactivations of 3 distances (5, 4, and 3 mm) at 37 degrees C in the canine position. Force-deflection measurements were recorded from the deactivations only. Forces produced during deactivation, at deflections of 2.5, 2.0, and 1.5 mm, were compared by analysis of variance. Significant differences (P < 0.0001) in forces were observed among the wires at the various deflections. All wires exhibited superelastic behavior, and rankings were derived according to statistically significant differences for each deflection distance.
    [Abstract] [Full Text] [Related] [New Search]