These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Safety and efficacy of single bolus anticoagulation with enoxaparin for chronic hemodialysis. Results of an open-label post-certification study.
    Author: Klingel R, Schwarting A, Lotz J, Eckert M, Hohmann V, Hafner G.
    Journal: Kidney Blood Press Res; 2004; 27(4):211-7. PubMed ID: 15273423.
    Abstract:
    BACKGROUND: Low-molecular-weight heparin (LMWH) is supposed to be advantageous compared to unfractionated heparin for chronic hemodialysis (HD) with respect to lipid and bone metabolism, polymorphonuclear cell stimulation, induction of antibody-mediated thrombocytopenia, and aldosterone suppression. Due to longer biological half-life, LMWH offers the possibility of single bolus administration. METHODS: To assess safety and efficacy of single bolus anticoagulation with enoxaparin for chronic HD, 781 stable HD patients from 79 German dialysis centers (mean age 62 years; 31% ESRD due to diabetes mellitus) were monitored by clinical and laboratory parameters for 32 weeks. Additionally, in a single dialysis center, 22 chronic HD patients were investigated by molecular markers of coagulation during chronic HD under conditions of single bolus or continuous anticoagulation regimens. Anti-Xa activity and the thrombin- antithrombin-III complex (TAT) were determined before the enoxaparin bolus, after 15 min, 2 h, and at the end of HD in venous and arterial blood lines. RESULTS: Chronic HD was performed in 24,117 HD treatments with enoxaparin at a median dose of 70.1 IU/kg (5,000 IU median total dose) for single bolus anticoagulation. In 83.0% of HD treatments, enoxaparin was given as single bolus. In 98.3% of patients no adverse event was reported. No drug-related severe adverse event occurred. Significant clotting problems were observed in only 0.3% of HD treatments with single bolus anticoagulation. As assessed in 257 HD treatments, essentially identical anti-Xa levels were detected at the end of HD with single bolus (50 IU/kg) or continuous (mean total dose 43 IU/kg) anticoagulation regimens. Bolus anticoagulation resulted in higher TAT generation at the end of HD. However, this was not associated with increased macroscopic clot formation. CONCLUSION: Single bolus anticoagulation with enoxaparin was safe and effective for chronic HD. For a duration of 4 h HD, a median dose of 70 IU/kg can be recommended for regular use, which is in accordance with the manufacturer's instructions for use of enoxaparin recommending a range of 50-100 IU/kg.
    [Abstract] [Full Text] [Related] [New Search]