These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Analysis of corticosteroids by high performance liquid chromatography-electrospray mass spectrometry. Author: Panusa A, Ottaviani M, Picardo M, Camera E, Gagliardi L, Chimenti P, Granese A, Tonelli D. Journal: Analyst; 2004 Aug; 129(8):719-23. PubMed ID: 15284915. Abstract: A high performance liquid chromatography electrospray mass spectrometry (HPLC-ESI-MS) method, for the detection of corticosteroids in cosmetics has been developed. A water-acetonitrile linear gradient on a C-18 reversed-phase column was found to be suitable in separating triamcinolone and its main derivatives, which greatly differ in lipophilicity. Detection was performed in negative electrospray ionisation mode. Good correlation between peaks areas and solutions concentration was found in the range 0.05-10.0 micro g ml(-1) and the detection limits resulted in the range of 20-45 pg injected. The method was successfully applied to the analysis of real samples of shampoo.[Abstract] [Full Text] [Related] [New Search]