These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Large perigraft seroma after aortoiliac bypass with an expanded polytetrafluoroethylene graft: report of a case.
    Author: Sugimoto T, Kitade T, Nishikawa H, Koyama T, Hatta T, Kurisu S.
    Journal: Surg Today; 2004; 34(8):698-700. PubMed ID: 15290402.
    Abstract:
    A 63-year-old man who had undergone aortoiliac bypass with an expanded polytetrafluoroethylene (PTFE) graft was referred to our hospital for investigation and treatment of a possible pseudoaneurysm of the abdominal aorta. A tender, pulsatile, and bulging mass, about the size of an adult fist, was palpated around the navel. Enhanced computed tomography (CT) showed a large low-density area around the abdominal aorta and PTFE graft, and aortography showed a patent graft with no anastomotic leakage. Operative inspection revealed that the pulsatile mass was a large perigraft seroma, and we replaced the PTFE graft with a new woven Dacron graft. The patient has been well with no sign of recurrence for 1 year, although close long-term follow-up is mandatory.
    [Abstract] [Full Text] [Related] [New Search]