These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Trace element determination in seawater by ICP-SFMS coupled with a microflow nebulization/desolvation system.
    Author: Turetta C, Cozzi G, Barbante C, Capodaglio G, Cescon P.
    Journal: Anal Bioanal Chem; 2004 Sep; 380(2):258-68. PubMed ID: 15322788.
    Abstract:
    Direct and simultaneous determination of Al, Ag, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Pb, Sb, U, V and Zn in diluted (1:10 v:v) seawater from the Antarctic Ocean and the Venice Lagoon at the ng mL(-1) and pg mL(-1) level has been performed by using an inductively coupled plasma sector field mass spectrometer (ICP-SFMS). Samples were analysed by using a PFA microflow nebulizer coupled with a desolvation system or a PFA microflow nebulizer coupled with a Teflon spray chamber, respectively. Measurements were carried out at low (LR, m/Delta m=300), medium (MR, m/Delta m=3,000) and high (HR, m/Delta m=7,500) resolutions depending on the studied isotope. To avoid contamination, sample pre-treatment was carried out in a clean laboratory equipped with a Class 100 vertical laminar flow hood. Concentration ranges (minimum-maximum in ng mL(-1)) found in the Antarctic seawater samples (in depth profiles) were: Ag 0.0004-0.0018, As 0.69-1.32, Cd 0.031-0.096, Co 0.018-0.065, Cr 0.18-0.46, Cu 0.04-1.58, Fe 0.13-1.63, Mn 0.02-0.12, Mo 5.97-12.46, Pb 0.007-0.074, Sb 0.033-0.088, U 0.5-1.9, V 0.6-2.5 and Zn 0.16-0.80. Concentration ranges (min-max in ng mL(-1)) found in the Venice Lagoon water samples (temporal profile from a benthic chamber experiment) were: Al 0.24-0.61, Ag 0.007-0.031, As 1.42-2.27, Cd 0.050-0.182, Co 0.440-1.461, Cr 0.15-0.34, Cu 0.81-2.46, Fe 0.25-1.66, Mn 11.6-31.7, Mo 6.50-10.6, Pb 0.047-0.225, Sb 0.240-0.492, U 1.7-3.3, V 1.3-2.8 and Zn 5.20-21.5. The detection limits range between 0.06 pg mL(-1) for Ag and U to 15 pg mL(-1) for Fe. In order to check the accuracy of the analytical procedure, measurements of the trace elements in a certified reference material (coastal Atlantic seawater, CASS-4-NRCC) were compared with the certified values. In addition, the results from the Antarctic and Venice Lagoon samples were compared with those obtained by using different analytical techniques.
    [Abstract] [Full Text] [Related] [New Search]