Search MEDLINE/PubMed
Title: Development of a pMOSFET sensor with a Gd converter for low energy neutron dosimetry. Author: Lee NH, Kim SH, Youk GU, Park IJ, Kim YM. Journal: Radiat Prot Dosimetry; 2004; 110(1-4):277-81. PubMed ID: 15353659. Abstract: A pMOSFET having a 10 microm thick Gadolinium (Gd) layer has been invented as a slow neutron sensor. When slow neutrons are incident to the Gd layer, conversion electrons, which generate electron-hole pairs in the SiO2 layer of the pMOSFET, are generated by a neutron capture process. The holes are easily trapped in the oxide and act as positive-charge centres in the oxide. Due to the induced charges, the threshold turn-on voltage of the pMOSFET is changed. The developed sensors were tested at a neutron beam port of the HANARO research reactor and a 60Co irradiation facility to investigate slow neutron response and gamma ray contamination, respectively. The resultant voltage change was proportional to the accumulated neutron dose and it was very sensitive to slow neutrons. Moreover, ionising radiation contamination was negligible. It can also be used in a mixed radiation field by subtracting the voltage change of a pMOSFET without Gd from that of the Gd-pMOSFET.[Abstract] [Full Text] [Related] [New Search]