  • Title: Dependence of the characteristics of bubbles on types of sonochemical reactors.
    Author: Yasui K, Tuziuti T, Iida Y.
    Journal: Ultrason Sonochem; 2005 Jan; 12(1-2):43-51. PubMed ID: 15474951.
    Abstract:
    Computer simulations of bubble oscillations in liquid water irradiated by an ultrasonic wave have revealed that the characteristic of bubbles depends on types of sonochemical reactors: a horn-type reactor and a standing-wave type reactor. When the acoustic amplitude is large at 20 kHz, the bubble content is mostly water vapor even at the end of the bubble collapse and the temperature inside a bubble at the collapse is relatively low. On the other hand, when the acoustic amplitude is relatively low, the bubble content is mostly noncondensable gas at the end of the bubble collapse and the bubble temperature is relatively high. In a horn-type sonochemical reactor, the former type of bubbles are dominant because many bubbles exist near the horn-tip where the acoustic amplitude is large, while in a standing-wave type reactor the latter type of bubbles are dominant because the Bjerknes force gathers bubbles at a region where acoustic amplitude is relatively low.