These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Determination of linderane in root tuber of Lindera aggregata by HPLC].
    Author: Cai LH, Chou GX, Wang ZT, Li YG, Xu DR, Xu LS.
    Journal: Zhongguo Zhong Yao Za Zhi; 2004 Jul; 29(7):657-9. PubMed ID: 15503773.
    Abstract:
    OBJECTIVE: To provide scientific basis for quality control of Lindera aggregata. METHOD: HPLC analytical method was established using a Lichrospher C18 column and acetonitrile-water (56:44) as the mobile phase, detected at 235 nm. RESULT: The linear range of linderane is between 0.0642 - 0.5774 microg, the average recovery was 98.4%, RSD1.7% (n = 9). CONCLUSION: Contents of linderane in commercially available and collected samples were from 0.028% to 0.123% and from 0.056% to 0.222% respectively.
    [Abstract] [Full Text] [Related] [New Search]