These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Validation of a simplified field-adapted procedure for routine determinations of methyl mercury at trace levels in natural water samples using species-specific isotope dilution mass spectrometry. Author: Lambertsson L, Björn E. Journal: Anal Bioanal Chem; 2004 Dec; 380(7-8):871-5. PubMed ID: 15517198. Abstract: A field-adapted procedure based on species-specific isotope dilution (SSID) methodology for trace-level determinations of methyl mercury (CH(3)Hg(+)) in mire, fresh and sea water samples was developed, validated and applied in a field study. In the field study, mire water samples were filtered, standardised volumetrically with isotopically enriched CH(3) (200)Hg(+), and frozen on dry ice. The samples were derivatised in the laboratory without further pre-treatment using sodium tetraethyl borate (NaB(C(2)H(5))(4)) and the ethylated methyl mercury was purge-trapped on Tenax columns. The analyte was thermo-desorbed onto a GC-ICP-MS system for analysis. Investigations preceding field application of the method showed that when using SSID, for all tested matrices, identical results were obtained between samples that were freeze-preserved or analysed unpreserved. For DOC-rich samples (mire water) additional experiments showed no difference in CH(3)Hg(+) concentration between samples that were derivatised without pre-treatment or after liquid extraction. Extractions of samples for matrix-analyte separation prior to derivatisation are therefore not necessary. No formation of CH(3)Hg(+) was observed during sample storage and treatment when spiking samples with (198)Hg(2+). Total uncertainty budgets for the field application of the method showed that for analyte concentrations higher than 1.5 pg g(-1) (as Hg) the relative expanded uncertainty (REU) was approximately 5% and dominated by the uncertainty in the isotope standard concentration. Below 0.5 pg g(-1) (as Hg), the REU was >10% and dominated by variations in the field blank. The uncertainty of the method is sufficiently low to accurately determine CH(3)Hg(+) concentrations at trace levels. The detection limit was determined to be 4 fg g(-1) (as Hg) based on replicate analyses of laboratory blanks. The described procedure is reliable, considerably faster and simplified compared to non-SSID methods and thereby very suitable for routine applications of CH(3)Hg(+) speciation analysis in a wide range of water samples.[Abstract] [Full Text] [Related] [New Search]