These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Interaction between nesiritide and a heparin-coated pulmonary artery line during an infusion for decompensated heart failure. Author: Baroletti SA, Wahlstrom HD. Journal: Pharmacotherapy; 2004 Nov; 24(11):1634-7. PubMed ID: 15537565. Abstract: STUDY OBJECTIVE: Because it is known that intravenous nesiritide is not compatible with unfractionated heparin, we sought to determine the effect that heparin coating on a pulmonary artery catheter may have on the efficacy of a nesiritide infusion. METHODS: The efficacy of a nesiritide infusion given through a heparin-coated pulmonary artery line was compared with that of a nesiritide infusion administered in the same patient through a heparin-free peripheral line. RESULTS: The rate of infusion was titrated to maintain consistent hemodynamic parameters. When nesiritide was administered through a heparin-coated line, the infusion rate escalated from 0.01 microg/kg/minute to 0.07 microg/kg/minute. After the route of administration was switched to a heparin-free line, the same hemodynamic parameters were maintained. The heparin-free line made it possible to reduce the infusion rate by 57.1% over the next 24 hours to 0.03 microg/kg/minute. CONCLUSION: The interaction of nesiritide with heparin-coated pulmonary artery lines has the potential to be clinically significant. Clinicians should be educated about this potential interaction. Nesiritide should be infused only through heparin-free lines.[Abstract] [Full Text] [Related] [New Search]