These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Evaluation by Doppler echocardiography of hemodynamic profil of mitral bileaflet prothesis. Report on 90 cases]. Author: Drissa H, Ben Salah F, Zaouali RM. Journal: Tunis Med; 2004 Jul; 82(7):648-55. PubMed ID: 15552022. Abstract: From 1981 to 1999 Mitral bileaflet prosthesis was implanted to 90 patients. Doppler echocardiography was performed for these patients between January and March 2002 with a mean deadline of 111 months after the intervention. 36 were women (40%) and 54 were men (60%) the mean age was 41 years (20 - 70 years) The mitral bileaflet prosthesis was a Saint Jude in 65 cases, Jyros 8 cases, Carbomédics 7 cases, Sorin Bicarbon 7 cases, Edwards Duromédics 2 cases et an ON-X in one case. The maximal transprosthetic gradient was 15.7 mm Hg +/- 5.06 (6.25 mm Hg). The mean transprosthetic gradient was 5.6 mm Hg +/- 1.07 (39.5 mmHg). The mean prosthesis functional area 2.37 cm2 +/- 0.44 (1.75 cm2 et 3.60 cm2). Maximal gradient, mean gradient and prosthesis functional area are independent from kind mitral bileaflet prosthesis and from the prosthesis size.[Abstract] [Full Text] [Related] [New Search]