These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Influence of left ventricular function on outcome of patients treated with implantable defibrillators.
    Author: Kim SG, Fisher JD, Choue CW, Gross J, Roth J, Ferrick KJ, Brodman R, Furman S.
    Journal: Circulation; 1992 Apr; 85(4):1304-10. PubMed ID: 1555274.
    Abstract:
    BACKGROUND: The outcomes of patients treated with implantable defibrillators were compared between patients with left ventricular ejection fraction greater than or equal to 30% and less than 30%. METHODS AND RESULTS: Of 68 consecutive patients treated with implantable defibrillators, 40 patients (group 1) had left ventricular ejection fraction greater than or equal to 30%, and 28 patients (group 2) had left ventricular ejection fraction less than 30%. Sudden death, surgical mortality, nonsudden arrhythmia-related death (death within 24 hours after an arrhythmic event despite initial termination of the arrhythmia by the implantable defibrillator), total arrhythmia-related death (including sudden death, surgical death, and nonsudden arrhythmia-related death), and total cardiac death were compared between the two groups. Surgical mortality was 4.4% (0% in group 1, 11% in group 2). During the follow-up of 31 +/- 27 months, actuarial survival rates free of events were 97%, 97%, and 97% in group 1 and 96%, 91%, and 82% in group 2 at 12, 24, and 36 months, respectively, for sudden death (p = NS); 97%, 97%, and 97% in group 1 and 85%, 81%, and 72% in group 2 at 12, 24, and 36 months, respectively, for sudden death and surgical mortality (p less than 0.05); 97%, 97%, and 97% in group 1 and 82%, 78%, and 70% in group 2 at 12, 24, and 36 months, respectively, for total arrhythmia-related death (p less than 0.05); and 95%, 95%, and 95% in group 1 and 82%, 69%, and 57% in group 2 at 12, 24, and 36 months, respectively, for total cardiac death (p less than 0.05). Four (57%) of seven nonsudden cardiac deaths during the initial 36-month follow-up period were causally related to arrhythmia (three surgical deaths and one arrhythmia-related nonsudden death). CONCLUSIONS: The outcome of patients treated with implantable defibrillators is strongly influenced by the degree of left ventricular dysfunction. In group 1 patients, surgical mortality, sudden death, and total cardiac death are rare. In group 2, sudden death rate may not be markedly different from that of group 1 patients. However, the risk of therapy (surgical mortality) is high. Many nonsudden cardiac deaths are causally related to arrhythmia (surgical mortality or nonsudden arrhythmia-related death). Therefore, the survival rate free of total arrhythmia-related death is significantly lower in group 2 (70% versus 97% in group 1 at 3 years). Further studies are needed to determine the roles of defibrillator therapy and other therapies in various clinical settings.
    [Abstract] [Full Text] [Related] [New Search]