These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: VCSEL based detection of water vapor near 940nm. Author: Cattaneo H, Laurila T, Hernberg R. Journal: Spectrochim Acta A Mol Biomol Spectrosc; 2004 Dec; 60(14):3269-75. PubMed ID: 15561608. Abstract: A vertical-cavity surface-emitting laser (VCSEL) was used to study the absorption spectrum of water vapor in the 940nm region. Measurements were performed in ambient air at room temperature and in a hydrogen-oxygen flame over the temperature range of 1500-1800K. Several rotational absorption lines within the 2v1 + v3 vibrational band were measured. The absorption spectra were well resolved, which demonstrates the feasibility of VCSEL-based spectroscopic measurements of water vapor at room and high-temperature in this spectral region. The results were in good agreement with the values obtained from the HITRAN-96 database.[Abstract] [Full Text] [Related] [New Search]