These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Antigen detection in human respiratory Coronavirus infections by monoclonal time-resolved fluoroimmunoassay.
    Author: Hierholzer JC, Halonen PE, Bingham PG, Coombs RA, Stone YO.
    Journal: Clin Diagn Virol; 1994 Jun; 2(3):165-79. PubMed ID: 15566763.
    Abstract:
    BACKGROUND: The diagnosis of respiratory infections by detecting viral antigens has received considerable attention using immunofluorescent assays (IFA) and enzyme immunoassays (EIA). Time-resolved fluoroimmunoassay (TR-FIA) has been developed for several viruses. OBJECTIVES: To prepare monoclonal antibodies to coronavirus strains, to incorporate them into a TR-FIA, and test the assay on clinical specimens. STUDY DESIGN: Monoclonal antibodies were prepared to the N nucleoprotein of the two human respiratory coronaviruses, HCV strains 229E and OC43. Monoclonals to both viruses were completely type-specific; they did not cross-react between themselves or with multiple strains of other respiratory viruses. These antibodies were configured into optimized EIA and TR-FIA tests. The all-monoclonal tests were then compared to polyclonal EIA tests in terms of their ability to detect virus in clinical specimens. RESULTS: The all-monoclonal TR-FIA was uniformly the most sensitive, detecting virus in all 13 229E-positive specimens compared to 69% for the monoclonal EIA and 54% for the polyclonal EIA test. Similar results were obtained for 10 OC43-positive specimens: 100% in TR-FIA, 90% in monoclonal EIA, and 80% in polyclonal EIA. For 229E in TR-FIA, mean positive/negative (P/N) ratios were 143 for 229E-positive human embryonic lung fibroblast (HLF) cell culture fluids and 10 for positive nasopharyngeal aspirate specimens; for OC43 in TR-FIA, mean P/N values were 964 for OC43-positive rhabdomyosarcoma (RD) cell culture fluids and 174 for positive NPA specimens. The sensitivities of the TR-FIA were determined with purified virions to be 0.308 ng virus per well for HCV-229E and 0.098 ng virus per well for HCV-OC43. CONCLUSIONS: This rapid and sensitive test appears to be much more sensitive than traditional antigen detection assays but will require more extensive field testing on clinical specimens.
    [Abstract] [Full Text] [Related] [New Search]