These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Surgical outcome of staged univentricular-type repairs for patients with univentricular physiology and pulmonary hypertension.
    Author: Chowdhury UK, Airan B, Kothari SS, Sharma R, Subramaniam GK, Bhan A, Saxena A, Juneja R, Venugopal P.
    Journal: Indian Heart J; 2004; 56(4):320-7. PubMed ID: 15586741.
    Abstract:
    BACKGROUND: There is no consensus about the most appropriate limits of pulmonary artery pressure and vascular resistance in case of patients undergoing univentricular or one and one-half ventricular repair. This study was conducted to analyze the mortality and morbidity of a heterogenous group of patients with a functionally univentricular heart and pulmonary artery hypertension, undergoing pulmonary artery banding followed by univentricular-type repairs. METHODS AND RESULTS: Out of 254 patients undergoing pulmonary artery banding for a functionally univentricular heart with increased pulmonary blood flow, 148 patients underwent definitive second stage surgery. Post-band hemodynamic evaluation revealed persistently high pulmonary artery pressure (> 18 mmHg), and pulmonary vascular resistance (>2.0 Woods units/m2) in 78.3% patients. Sixteen patients with moderate right ventricular hypoplasia were given a one and one-half ventricle repair (Group I), 82 patients a bidirectional Glenn connection (Group II), and 50 patients a fenestrated total cavopulmonary connection (Group III). The overall mortality following second stage surgery for the high pulmonary artery pressure group (n=116) was 30.17%, while none of the low pulmonary artery pressure group died (p=0.0009). Pulmonary hypertensive crises and/or systemic desaturation were the main causes of death at second stage repair. All mortality occurred in patients with mean pulmonary artery pressure > 18 mmHg and pulmonary vascular resistance > 3.5 Woods units/m2. Survivors from this group had persistent morbidity in the form of superior vena caval syndrome and suboptimal oxygen saturation (70-75%). CONCLUSIONS: It is advisable not to proceed with definitive second stage repair if post-pulmonary artery banding mean pulmonary artery pressure is over 25 mmHg and pulmonary vascular resistance exceeds 4.0 Woods units/m2. These patients may possibly be deemed to have undergone definitive palliation during their pulmonary artery banding.
    [Abstract] [Full Text] [Related] [New Search]