These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Development of fluorescence change-based, reagent-less optic immunosensor.
    Author: Aoyagi S, Kudo M.
    Journal: Biosens Bioelectron; 2005 Feb 15; 20(8):1680-4. PubMed ID: 15626628.
    Abstract:
    A reagent-less, regenerable and portable optic immunosensor was developed. A model sample, immunoglobulin G (IgG), was detected with this system based on changes in fluorescent intensity of fluorescent labeled protein A with specific reactivity to IgG depending on a reaction between the proteins. A glass plate immobilized with Qdot-labeled protein A was placed on the top of optic fibers designed for both excitation and fluorescence emission. The optic fibers with the Qdot-labeled protein A-immobilized glass plate were inserted into a solution of pH 7.4 phosphate buffered saline. After stabilization of the fluorescence intensity, IgG was added and the time-course of the fluorescence intensity was measured on a fluorometer connected with the optic fibers. Furthermore, the fluorescence response of a transient state was evaluated with the same system. When the Qdot-labeled protein A bound to IgG, fluorescence intensity decreased because of the inhibition by IgG. The degree of fluorescence decrease depends on the IgG concentration at a steady state and also in a transient state.
    [Abstract] [Full Text] [Related] [New Search]