These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Acute complications of MammoSite brachytherapy: a single institution's initial clinical experience. Author: Harper JL, Jenrette JM, Vanek KN, Aguero EG, Gillanders WE. Journal: Int J Radiat Oncol Biol Phys; 2005 Jan 01; 61(1):169-74. PubMed ID: 15629608. Abstract: PURPOSE: To report the acute complications incurred by the initial 37 patients who underwent accelerated partial breast irradiation with the MammoSite balloon breast brachytherapy applicator at the Medical University of South Carolina. METHODS AND MATERIALS: Between May 2002 and March 2003, 37 patients with ductal carcinoma in situ or invasive carcinoma had MammoSite brachytherapy catheters successfully place after lumpectomy by one of four surgeons and were deemed eligible for high-dose-rate brachytherapy. An open technique was used in 32 implants and the scar entry technique was used in 5 implants. Patients had Stage pTis-pT2N1 with negative margins. A dose of 34 Gy was prescribed to 1 cm from the balloon surface using (192)Ir high-dose-rate brachytherapy and was delivered in 10 fractions twice daily. CT was used to confirm that the balloon surface was adherent to the lumpectomy cavity and to measure the balloon surface to skin surface distance. CT images and daily fluoroscopic simulations were used for treatment planning. Patients were assessed for acute toxicity on the day of therapy completion and 4 weeks after therapy by the radiation oncologist. In addition, all available data from radiation, surgical, and medical oncology were retrospectively reviewed for documentation of complications. All patients in this series had a minimal follow-up of 3 months; the mean follow-up for all patients was 7 months. RESULTS: The acute complications were categorized as operative wound complications, infections, skin toxicity, seromas, or catheter failures. Operative wound complications occurred in 3 patients (8%). Radiation Therapy Oncology Group Grade 2 and Grade 3 toxicity occurred in 2 (5.4%) and 1 (2.7%) patient, respectively. Six (16.2%) developed wound infections and 12 (32.4%) seromas. Catheter failures due to leak occurred in 2 patients (5.4%) and rupture in 3 (8%). CONCLUSION: The types of complications in this experience were similar to those in the Phase I trial of the MammoSite brachytherapy applicator. However, catheter failure due to leak occurred in our experience and was not described in the Phase I trial. The incidence of complications was greater in our series than in the Phase I trial; however, differences in toxicity scoring and the length of follow-up between the two series impeded direct comparisons. The incidences of complications over time reflect the steep learning curve for accelerated partial breast irradiation using the MammoSite brachytherapy applicator. Finally, radiation recall dermatitis developed in 1 patient treated after this review was completed.[Abstract] [Full Text] [Related] [New Search]