Search MEDLINE/PubMed
Title: Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic hyperinflation in mechanically ventilated patients. Author: Blanch L, Bernabé F, Lucangelo U. Journal: Respir Care; 2005 Jan; 50(1):110-23; discussion 123-4. PubMed ID: 15636649. Abstract: Severe airflow obstruction is a common cause of acute respiratory failure. Dynamic hyperinflation affects tidal ventilation, increases airways resistance, and causes intrinsic positive end-expiratory pressure (auto-PEEP). Most patients with asthma and chronic obstructive pulmonary disease have dynamic hyperinflation and auto-PEEP during mechanical ventilation, which can cause hemodynamic compromise and barotrauma. Auto-PEEP can be identified in passively breathing patients by observation of real-time ventilator flow and pressure graphics. In spontaneously breathing patients, auto-PEEP is measured by simultaneous recordings of esophageal and flow waveforms. The ventilatory pattern should be directed toward minimizing dynamic hyperinflation and auto-PEEP by using small tidal volume and preserving expiratory time. With a spontaneously breathing patient, to reduce the work of breathing and improve patient-ventilator interaction, it is crucial to set an adequate inspiratory flow, inspiratory time, trigger sensitivity, and ventilator-applied PEEP. Ventilator graphics are invaluable for monitoring and treatment decisions at the bedside.[Abstract] [Full Text] [Related] [New Search]