These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Characterization of batch-microfabricated scanning electrochemical-atomic force microscopy probes.
    Author: Dobson PS, Weaver JM, Holder MN, Unwin PR, Macpherson JV.
    Journal: Anal Chem; 2005 Jan 15; 77(2):424-34. PubMed ID: 15649037.
    Abstract:
    A procedure for the batch microfabrication of scanning electrochemical-atomic force microscopy (SECM-AFM) probes is described. The process yields sharp AFM tips, incorporating a triangular-shaped electrode (base width 1 microm, height 0.65 microm) at the apex. Microfabrication was typically carried out on (1)/(4) 3-in. wafers, yielding 60 probes in each run. The measured spring constant of the probes was in the range 1-1.5 N m(-1). To date, processing has been carried out twice successfully, with an estimated success rate for the fabrication process in excess of 80%, based on field emission-scanning electron microscopy imaging of all probes and current-voltage measurements on a random selection of approximately 30 probes. Steady-state voltammetric measurements for the reduction of Ru(NH(3))(6)(3+) in aqueous solution indicate that the electrode response is well-defined, reproducible, and quantitative, based on a comparison of the experimental diffusion-limited current with finite element simulations of the corresponding mass transport (diffusion) problem. Topographical imaging of a sputtered Au film with the SECM-AFM probes demonstrates lateral resolution comparable to that of conventional Si(3)N(4) AFM probes. Combined electrochemical-topographical imaging studies have been carried out on two model substrates: a 10-microm-diameter disk ultramicroelectrode (UME) and an array of 1-microm-diameter UMEs, spaced 12.5 microm apart (center to center). In both cases, an SECM-AFM probe was first employed to image the topography of the substrates. The tip was then moved back a defined distance from the surface and use to detect Ru(NH(3))(6)(2+) produced at the substrate, biased at a potential to reduce Ru(NH(3))(6)(3+), present in bulk solution, at a diffusion-controlled rate (substrate generation-tip collection mode). These studies establish the success of the batch process for the mass microfabrication of SECM-AFM tips.
    [Abstract] [Full Text] [Related] [New Search]