These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Simultaneous determination of trans, transmuconic acid and s-phenylmercapturic acid by high pressure liquid chromatography and its application. Author: Tharnpoophasiam P, Kongtip P, Wongwit W, Fungladda W, Kitayaporn D. Journal: Southeast Asian J Trop Med Public Health; 2004 Sep; 35(3):717-23. PubMed ID: 15689094. Abstract: The simultaneous determination of urinary trans,trans-muconic acid (t,t-MA) and S-phenylmercapturic acid (S-PMA) was performed by liquid extraction with ethyl acetate and reversed-phase high performance liquid chromatography (RP-HPLC) on a Hypersil-ODS column using the gradient mobile phase of methanol and 0.0012 N perchloric acid and diode array detection at 205 and 264 nm for S-PMA and t,t-MA, respectively. The retention times for t,t-MA and S-PMA were 3.8 and 12.3 minutes, respectively. The recoveries of t,t-MA and S-PMA were > 97%; between-day precisions were all within 8% RSD (100x SD/mean). The method was applied to analyze the urinary t,t-MA and S-PMA of 59 service station attendants exposed to average benzene concentrations in the air of 0.20+/-0.18 ppm. Significant differences in pre-shift and post-shift urinary t,t-MA between smokers and non-smokers were found.[Abstract] [Full Text] [Related] [New Search]