These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparison of sampling positions when measuring personal exposure to solder fume. Author: Simpson AT. Journal: Ann Occup Hyg; 2005 Jul; 49(5):439-42. PubMed ID: 15689396. Abstract: A sampling device based on a telephone headset was developed and used to support a sampler close to the mouth during personal exposure monitoring of solder fume. In a field trial, it was compared with the established method of mounting the sampler on the arm of a pair of spectacles, and a linear correlation was evident between the two positions (slope 1.56 +/- 0.05, r(2) = 0.98). Although the headset sampler held the sampler closer to the breathing zone, experience showed that the spectacles position was less intrusive on the subject and allowed a more consistent and stable sampling position. On balance, the spectacles position was the preferred sampling location.[Abstract] [Full Text] [Related] [New Search]