  • Title: Validation of ELISA test kits for detection of beta-agonist residues in meat.
    Author: Ponniah J, Muhammad K, Abdullah S, Ganapathy KK, bt Sheikh Abdul Hamid N.
    Journal: Southeast Asian J Trop Med Public Health; 2004 Jun; 35(2):481-7. PubMed ID: 15691160.
    Abstract:
    Three ELISA test kits, the Randox ELISA beta-agonist test kit, Euro-Diagnostica test kit, and Ridascreen beta-agonist test kit, were evaluated for screening of meat and liver for beta-agonist residues in fortified and field-incurred samples. It was found that the Randox beta-agonist test kit was more suitable as a screening tool due to its accuracy, ease of use, and lower cost. The tests were able to detect beta-agonist residues at the minimum level of detection, as claimed by the suppliers. The performance of the method as assessed through recovery rates of beta-agonists in fortified samples was satisfactory with a low coefficient of variation (1-3%). Repeatability, as measured through the coefficient of correlation was also satisfactory. For field-incurred positive samples, the test kit showed a sensitivity of 100% and a low rate of false positives for goat and cow tissues. However, a high rate of apparent false positives was obtained for tissues of swine.