These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A randomised controlled trial in the north of England examining the effects of skin-to-skin care on breast feeding.
    Author: Carfoot S, Williamson P, Dickson R.
    Journal: Midwifery; 2005 Mar; 21(1):71-9. PubMed ID: 15740818.
    Abstract:
    OBJECTIVE: to examine the effect of early skin-to-skin contact between mothers and their healthy full-term babies on initiation and duration of breast feeding. DESIGN: a randomised controlled trial comparing skin-to-skin with routine care. SETTING: Warrington Hospital, Cheshire, UK. PARTICIPANTS: 204 mother and baby pairs; 102 randomised to each group. OUTCOME MEASURES: success of first breast feed, maternal satisfaction with skin-to-skin care and preference for future post-delivery care, baby-body temperature 1 hr after birth, partial or exclusive breast feeding at 4 months. FINDINGS: in the skin-to-skin group, 89 out of 98 (91%) babies had a successful first feed compared with 82 out of 89 (83%) in the routine care group. The difference in the success rate was 8%, 95% confidence interval (CI) (-1.6%, 17.6%); chi(2)=2.7; df=1; P=0.10. Forty-two out of 97 (43%) babies given skin-to-skin were partially or exclusively breast feeding at 4 months compared with 40 out of 100 (40%) of babies in the routine care group. The difference in breast-feeding rate at 4 months was 3.3%, 95% CI (-10.3%, 16.7% ); chi(2)=0.22; df=1; P=0.64. The mean temperature 1 hr after birth was higher with skin-to-skin than routine care. The difference in means was 0.15 degrees C; 95% CI (0.03, 0.28); P=0.02. A larger proportion of mothers (87/97 [90%]) were very satisfied with skin-to-skin care, compared with 60 out of 102 (59%) in the control group; 83 out of 97 (86%) of the mothers in the intervention group said that they would prefer to receive the same care in the future compared with 31 out of 102 (30%) mothers in the control group. CONCLUSIONS: the difference between the groups in the success rate for the first breast feed and rates at 4 months was not statistically significant. However, mothers who had skin-to-skin contact enjoyed the experience, and most reported that they would choose to have skin-to skin care in the future. In this, the largest trial to date, previous concerns about baby-body temperature after skin-to-skin care were dispelled.
    [Abstract] [Full Text] [Related] [New Search]