These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Activated sludge deflocculation under temperature upshifts from 30 to 45 degrees C.
    Author: Morgan-Sagastume F, Grant Allen D.
    Journal: Water Res; 2005 Mar; 39(6):1061-74. PubMed ID: 15766960.
    Abstract:
    Twelve independent batch experiments (<9h) with fresh municipal activated sludge were conducted to assess the occurrence and the mechanisms of deflocculation under a temperature shift from 30 to 45 degrees C. In each experiment, a transient reactor (2 L) was subjected to the temperature shift and a control reactor was operated at a constant temperature of 30 degrees C. The occurrence of deflocculation was demonstrated by the increase in turbidity and in the concentrations of biopolymers in the sludge supernatant from the transient reactor. The maximum levels of proteins in the supernatants ranged from 53 to 81 mg/L, for DNA from 34 to 36 mg/L, for humic compounds from 20 to 40 mg/L, and for carbohydrates from 21 to 31 mg/L. All the biopolymer concentrations in the control reactor remained below 5-10 mg/L. The release of biopolymers was accompanied by an increase in sludge supernatant conductivity (16-32% increase, up to 1.20 mS/cm), soluble chemical oxygen demand (from 129 to 440 mg/L), total suspended solids (>25 mg/L up to 128 mg/L), and a decrease in the mixed liquor volatile suspended solids (up to 11%). The temperature shift was also found to inhibit microbial metabolism by reducing the sludge biomass substrate removal capacity, as measured by oxygen-uptake rates. The temperature shift had a marginal effect causing sludge lysis (as an increase in beta-galactosidase activity) and had no significant impact on sludge viability (live/dead ratio of bacterial cells). It was concluded that sludge deflocculation under a temperature shift from 30 to 45 degrees C involves the solubilisation of extracellular polymeric substances from the flocs and likely also floc fragmentation. In addition, sludge deflocculation and the inhibition of microbial metabolism explain the poor treatment performance observed in previous continuous reactors under similar temperature shifts.
    [Abstract] [Full Text] [Related] [New Search]