These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Rapid determination of trace Sb in plastic pipes for dringing water by GFAAS]. Author: Lu D, Qian YE. Journal: Guang Pu Xue Yu Guang Pu Fen Xi; 2004 Feb; 24(2):242-4. PubMed ID: 15769029. Abstract: A new method for the determination of trace Sb in plastic pipes for drinking water was found. Cu is used as a matrix modifier in the transverse-orientation Zeeman background dedution GFAAS to determine trace Sb in plastic pipes for drinking water rapidly. The ashing temperature and atomization temperature were obtained by optimization process. The influences of medium acidity were studied. The best measurement conditions were selected. The sensitivity and precision of the method were improved. Sb was detected directly with a linear range of 0.27-20.0 microg x L(-1). The equation of working curve is Y = 0.0068X - 0.0002, r = 0.9996. The characteristic mass of the method is 6.7 pg. The detection limit is 5.4 pg. The recovery is 92.2%-102.5%. The RSDs were obtained from the data of 6 determinations at the concentration level of 5.0, 10.0 and 20.0 microg x L(-1) is 6.47%, 4.97% and 2.45% respectively. The method is simple, rapid, accurate and of highly sensitive and precise. Satisfactory results are obtained.[Abstract] [Full Text] [Related] [New Search]