These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Effect of glazed and polished surface finishes on the friction coefficient of two low-fusing ceramics.
    Author: Schuh C, Kinast EJ, Mezzomo E, Kapczinski MP.
    Journal: J Prosthet Dent; 2005 Mar; 93(3):245-52. PubMed ID: 15775925.
    Abstract:
    STATEMENT OF PROBLEM: All-ceramic and metal-ceramic dental restorations are potentially harmful because they may wear opposing enamel. Wear is a multifactorial process; however, laboratory procedures can minimize the wear process, thus benefiting clinicians and manufacturers. PURPOSE: This in vitro investigation of wear evaluated the physical and tribological characteristics of 2 low-fusing ceramics and dental enamel. MATERIAL AND METHODS: Quantitative and qualitative analyses of 2 low-fusing ceramics (IPS d.Sign and Vita Omega 900) and enamel were performed using scanning electron microscopy, x-ray diffraction, and energy-dispersive analyses. Each ceramic was tested using 20 disks (10 mm x 3 mm), of which 10 were glazed and 10 were polished. Ten polished enamel specimens (6 mm x 7 mm) served as the control. The specimens were submitted to a Vickers hardness test for 30 seconds using a 200 g load. The coefficient of friction was determined by using a pin-on-disk test without lubrication (5 N load, 600 seconds, 120 RPM). The data were analyzed using a 1-way analysis of variance and Sheffe analysis (alpha=.05). RESULTS: The same chemical elements were found in both ceramics, and tetragonal leucite was the main component of the crystalline phases. The microhardness of the enamel was significantly different ( P <.05) between the glazed and polished ceramics. There was no significant difference found in the friction coefficient (mean +/- SD) of the enamel (0.286 +/- 0.174), glazed Vita Omega 900 (0.309 +/- 0.085), and glazed IPS d.Sign (0.253 +/- 0.068) specimens. The mean friction coefficient of the polished Vita Omega 900 (0.486 +/- 0.036) and IPS d.Sign (0.446 +/- 0.037) specimens was found to be significantly higher than the enamel and glazed specimens ( P <.05). CONCLUSIONS: Both ceramics tested presented similar chemical-structural and tribological characteristics. When glazed, they showed tribological similarity to dental enamel.
    [Abstract] [Full Text] [Related] [New Search]