These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Effect of cataract surgery with intraocular lens implant on frequency doubling perimetry.
    Author: Arvind H, George R, Baskaran M, Raju P, Ramesh SV, Paul PG, Vijaya L.
    Journal: Curr Eye Res; 2005 Feb; 30(2):123-8. PubMed ID: 15814470.
    Abstract:
    PURPOSE: To study the effect of cataract surgery with intraocular lens (IOL) on frequency doubling perimetry (FDP). METHODS: Patients aged 40 years or above seen at our outpatient clinic with no ocular pathology except for visually significant cataract and visual acuity 6/24 or better were eligible. They underwent FDP before and 4 to 6 weeks after cataract surgery with IOL. RESULTS: Screening test: Mean scores by three different scoring methods were 1.82 (3.21), 2.80 (5.54), 4.18 (9.18) before and 0.22 (0.51), 0.26 (0.63), 0.26 (0.69) after surgery (p = 0.002 0.001, < 0.0001). Threshold test: Mean deviation (MD) and pattern standard deviation (PSD) were -5.23 (3.08) and 5.15 (2.78) before and -2.94 [corrected] (2.49) (p < 0.0001) and 5.21 (1.780) (p = 0.63) after surgery. CONCLUSIONS: The screening test should be interpreted cautiously in the presence of cataract. On threshold testing, cataract surgery causes significant decrease in MD but no change in PSD.
    [Abstract] [Full Text] [Related] [New Search]