  • Title: Detection of West Nile virus RNA and antibody in frozen plasma components from a voluntary market withdrawal during the 2002 peak epidemic.
    Author: Tobler LH, Bianco C, Glynn SA, Schreiber GB, Dille BJ, Prince HE, Lanciotti RS, Linnen JM, Gallarda J, Shyamala V, Smith D, Kleinman SH, Busch MP, NHLBI Retrovirus Epidemiology Study (REDS).
    Journal: Transfusion; 2005 Apr; 45(4):480-6. PubMed ID: 15819666.
    Abstract:
    BACKGROUND: The US West Nile virus (WNV) epidemic in the summer and fall of 2002 included the first documented cases of transfusion-transmitted WNV infection. In December 2002, the FDA supported a voluntary market withdrawal by the blood banking community of frozen blood components collected in WNV high-activity areas. At the time, the prevalence of viremia and serologic markers for WNV in the blood supply was undefined. STUDY DESIGN AND METHODS: In collaboration with America's Blood Centers, 1468 frozen plasma components (of approx. 60,000 frozen units voluntarily withdrawn from the market) were selectively retrieved from the peak epidemic regions and season (June 23, 2002-September 28, 2002). These units were unlinked, subaliquoted, and tested by WNV enzyme immunoassays (EIAs; Focus Technologies and Abbott Laboratories) and nucleic acid amplification tests (NATs; Gen-Probe Inc. and Roche Molecular Systems). RESULTS: Of the 1468 EIA results from Abbott and Focus, 7 were anti-immunoglobulin M (IgM)- and anti-immunoglobulin G (IgG)-reactive by both assays, 8 and 1 were IgM-only-reactive, and 8 and 23 were IgG-only-reactive, respectively. NAT by Gen-Probe and Roche Molecular Systems yielded one RNA-positive, antibody-negative unit containing approximately 440 RNA copies per mL. An additional 10-fold replicate NAT testing by Gen-Probe on 14 of 15 IgM-reactive specimens yielded 2 additional IgM- and IgG-reactive units with low-level viremia (i.e., 7/10 and 2/10 replicates tested reactive). CONCLUSION: The prevalence of acute (RNA-positive) and recent (IgM-seroreactive) WNV infections indicates that transfusion risk in high-risk areas could have been considerable and that voluntary market withdrawal of frozen components likely averted some WNV transfusion transmissions. The existence of very-low-level viremic units raises concerns, because WNV minipool NAT screening will miss such units and individual NAT may not completely correct this situation.
    [Abstract] [Full Text] [Related] [New Search]