These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Oxygen-enhanced proton imaging of the human lung using T2.
    Author: Pracht ED, Arnold JF, Wang T, Jakob PM.
    Journal: Magn Reson Med; 2005 May; 53(5):1193-6. PubMed ID: 15844155.
    Abstract:
    Magnetic susceptibility gradients caused by tissue/air interfaces lead to very short T(2)* times in the human lung. These susceptibility gradients are dependent on the magnetic susceptibility of the respiratory gas and therefore should influence T(2)* relaxation. In this work, a technique for quantitative T(2)* mapping of the human lung during one breath hold is presented. Using this method, the lung T(2)* relaxation time was measured under normoxic (room air, 21% O(2)) and hyperoxic (100% O(2)) conditions to verify this assumption. The mean T(2)* difference between room air and 100% O(2) is about 10% and contains ventilation information, since only ventilated regions contribute to signal change due to different susceptibility gradients.
    [Abstract] [Full Text] [Related] [New Search]