Title: Determination of oxytetracycline in salmon by liquid chromatography with metal-chelate fluorescence detection. Author: Rupp HS, Anderson CR. Journal: J AOAC Int; 2005; 88(2):505-10. PubMed ID: 15859078. Abstract: A liquid chromatography (LC) method is described for the determination of oxytetracycline (OTC) in farmed Atlantic salmon muscle tissue. The method involves homogenization of salmon tissue, extraction of OTC into Mcllvaine-EDTA buffer, acid precipitation of proteins, cleanup through tandem solid-phase extraction cartridges (Strata-X and aminopropyl), elution with mobile phase containing slightly alkaline buffer and Mg2+, and LC separation with metal-chelate induced fluorescence detection. Salmon tissue was fortified with 0.10, 0.25, 0.50, 0.75, and 1.0 microg/g (ppm) oxytetracycline. Average absolute recoveries were 84, 76, 70, 76, and 85%, respectively, with relative standard deviation (RSD) values all less than 9%. The interassay average recovery was 78%, with a 4.2% RSD. Determination was based on a standard graph using peak areas with standard solutions equivalent to 0.0625, 0.125, 0.25, 0.50, and 1.0 ppm in tissue. A set of 5 matrix controls (unfortified salmon tissue) were also analyzed, in which no OTC was detected. The lowest standard was used as the limit of quantitation.[Abstract] [Full Text] [Related] [New Search]