These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Disruption of graft endothelium correlates with early failure after off-pump coronary artery bypass surgery. Author: Manchio JV, Gu J, Romar L, Brown J, Gammie J, Pierson RN, Griffith B, Poston RS. Journal: Ann Thorac Surg; 2005 Jun; 79(6):1991-8. PubMed ID: 15919298. Abstract: BACKGROUND: Saphenous vein graft failure after coronary artery bypass surgery may be as high as 5% to 10% in the first postoperative week. We hypothesized that identifying damage sustained by saphenous vein endothelium before grafting predicts early graft attrition after off-pump coronary artery bypass graft surgery. METHODS: Intraoperative graft flow, platelet function, and endothelial integrity were analyzed in 125 patients undergoing off-pump coronary artery bypass graft surgery. Endothelial integrity was assessed in an excess vein segment from each graft using immunohistochemistry (CD31 staining). Platelet function was monitored just before and immediately after revascularization and on postoperative days 1 and 3 using whole blood aggregometry, thrombelastography, and platelet activated clotting time. Platelet activation was monitored using flow cytometry. Intraoperative conduit blood flow, measured by transit time ultrasonography, was used to detect and rectify anastomotic problems. Early graft patency was determined on postoperative day 5 using gated multichannel computed tomography angiography. RESULTS: In 106 patients undergoing postoperative computed tomography evaluation, 10 vein grafts in 10 patients were discovered to have developed early thrombosis, representing 4% (10 of 217) of all vein grafts. Endothelial integrity was 10.75% +/- 17.56% in 10 grafts that failed early compared with 51.45% +/- 36.29% in patent grafts (p = 0.04). Perioperative platelet function and graft flow did not differ significantly between the two groups. CONCLUSIONS: Although endothelial disruption predicts early failure of bypass grafts, the importance of a hypercoaguable state and low graft flow as a cause of early graft thrombosis after off-pump coronary artery bypass graft surgery was not supported by our preliminary results. A means to assess, prevent, and treat intraoperative vein graft damage will likely improve early graft patency.[Abstract] [Full Text] [Related] [New Search]