These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Distributions of scatter-to-primary and signal-to-noise ratios per pixel in digital chest imaging.
    Author: Ullman G, Sandborg M, Dance DR, Hunt R, Alm Carlsson G.
    Journal: Radiat Prot Dosimetry; 2005; 114(1-3):355-8. PubMed ID: 15933136.
    Abstract:
    The aim of this work was to calculate distributions of scatter-to-primary ratios (epsilon(s)/epsilon(p)) and signal-to-noise ratios per pixel (SNRp) in chest images. Such distributions may provide useful information on how physical image quality (contrast, SNR) is distributed over the posterior/anterior (PA) chest image. A Monte Carlo computer program was used for the calculations, including a model of both the patient (voxel phantom) and the imaging system (X-ray tube, anti-scatter grid and image detector). The calculations were performed for three PA thicknesses 20, 24 and 28 cm. For a 24 cm patient, the epsilon(s)/epsilon(p) varies between 0.5 in the lung to 2.5 behind the spine and heart. The corresponding variation of the SNRp is a factor of 3, with the highest values in the lung. Increasing the patient thickness from 20 to 28 cm increases the epsilon(s)/epsilon(p) by a factor of 2.2 behind the spine and heart.
    [Abstract] [Full Text] [Related] [New Search]