Title: Cementless Zweymüller hip replacement: a short-term follow-up in Al Razi Hospital, Kuwait. Author: Pospula W, Noor TA, Al Rowaih A. Journal: Med Princ Pract; 2005; 14(4):255-9. PubMed ID: 15961936. Abstract: OBJECTIVE: To present initial experience of the first 71 cases of cementless total hip replacement in Al Razi Hospital. SUBJECT AND METHODS: Between 1996 and 2004, total hip replacement was performed in 71 patients (40 male, 31 female, average age 40.7 years, range 17-74) using Zweymüller cementless prosthesis. The patients were followed clinically and radiologically over an average period of 36 months (range 6-84). The results were assessed according to Merle d'Aubigne clinical score. Radiological assessment included position of the implant, behavior of the prosthesis/bone interface and signs of osteointegration. RESULTS: Average clinical score during the 3 years' follow-up period was 17.8 points. Most of the implants were in optimal positions. No significant radiological modifications of the implant-bone interface were observed. CONCLUSION: Zweymüller total hip prosthesis gives excellent clinical and radiological results in short-term follow-up.[Abstract] [Full Text] [Related] [New Search]