These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Sensitive non-isotopic assays for autoantibodies to IA-2 and to a combination of both IA-2 and GAD65. Author: Chen S, Willis J, Maclean C, Ananieva-Jordanova R, Amoroso MA, Brooking H, Powell M, Collins A, Bennett S, Mitchell S, Burne P, Furmaniak J, Smith BR. Journal: Clin Chim Acta; 2005 Jul 01; 357(1):74-83. PubMed ID: 15963796. Abstract: BACKGROUND: A sensitive ELISA for measurement of IA-2 autoantibodies has been developed and assessed. Also, a combination ELISA for detection of both GAD65 autoantibodies and IA-2 autoantibodies is described. METHODS: The IA-2 autoantibody assay is based on the ability of IA-2 autoantibodies to form a bridge between IA-2 intracellular fragment coated onto ELISA plate wells and liquid-phase IA-2 labelled with biotin. The combination ELISA uses plates coated with both IA-2 and GAD65 and a mixture of IA-2-biotin and GAD65-biotin. Assay sensitivity was assessed using the WHO reference (NIBSC 97/550) for islet cell antibodies. IA-2 autoantibody measurements by ELISA were compared with measurements in immunoprecipitation assays (IPAs) based on 125I or 35S labelled IA-2. Combination ELISA results were compared with results obtained for individual autoantibodies. RESULTS: As little as 15 units/mL of NIBSC 97/550 was detectable in the IA-2 autoantibody ELISA compared to 125 units/mL by 125I-IA-2 IPA. 110/216(51%) sera from patients with type 1 DM were positive in the IA-2 autoantibody ELISA while 97/216 (45%) and 91/216 (42%) were positive in the 125I-IA2 and 35S-IA-2 IPAs, respectively. The IA-2 autoantibody ELISA showed 100% specificity for type 1 DM. The combination ELISA was able to detect GAD65 and/or IA-2 autoantibodies in 183/216 (85%) diabetic sera and 183/216 (85%) were also found positive for autoantibodies to IA-2 and/or to GAD65 in the assays for individual antibodies. Autoantibody measurements in the individual autoantibody assays and in the combination ELISA showed good agreement by Pearson correlation (r=0.92, n=216, p<0.001) and by Bland and Altman analysis. CONCLUSIONS: Sensitive and specific ELISAs for measurement of autoantibodies to IA-2 and to a combination of IA-2 and GAD65 have been developed. These assays are suitable for screening large numbers of samples in diabetes prediction and prevention trials.[Abstract] [Full Text] [Related] [New Search]