  • Title: Failure of bedside ABO testing is still the most common cause of incorrect blood transfusion in the Barcode era.
    Author: Ahrens N, Pruss A, Kiesewetter H, Salama A.
    Journal: Transfus Apher Sci; 2005 Aug; 33(1):25-9. PubMed ID: 15964241.
    Abstract:
    BACKGROUND AND OBJECTIVES: ABO-incompatible red blood cell (RBC) transfusions are a major risk in transfusion medicine. Identification of factors leading to this hazard is important to improve transfusion safety. MATERIAL AND METHODS: All consecutive erroneous ABO-incompatible transfusions occurring from January 1997 to December 2004 at the Charité University Hospital in Berlin, Germany were analysed. RESULTS: A total of 343,432 RBC units were transfused, and eight patients erroneously received 13 ABO-incompatible RBC concentrates. The most frequent error was incorrect bedside testing (n=7). Intensive care treatment was required in two cases, but there were no fatal mistransfusions. Four patients had no or only mild reactions. CONCLUSION: Mistransfusions are still a considerable risk in transfusion medicine despite quality control systems and electronic data processing. An increase in transfusion safety may require the introduction of further systems, e.g. radio-frequency identification (RFID) tags.